Falls City Laboratory Extraction Arms

The laboratory extraction arm is comprised of thin-wall anodized aluminum tubes with polypropylene swivel joints. A frequent option selection is all polypropylene construction with stainless steel airstream components for highly corrosive airstreams. Additionally, these arms may be constructed of conductive polypropylene material for spark resistance and ATEX-rated explosive applications. Arm tube diameters range from two to four inches, and arm lengths range from two feet up to eight and a half feet. Arms can be paired with a wall or ceiling bracket, several optional hoods, or a suction nozzle. Falls City, Oregon Laboratory bench mount arms are an option and are available in three and four-inch diameter tubes up to six feet in length.

  • Various hood options for more efficient source capture include dome hoods, square hoods, flat screen hoods, metal hoods, and suction nozzles.
  • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
  • Wall brackets, ceiling brackets, and table mount brackets are available.
  • Arm diameters include 2", 3", and 4", and arm lengths include 25", 30", 39", 45",51", 53", 59", 65", 75", 79", 83", and 104".
  • Polypropylene (P.P.), ESD (spark forming applications), and ATEX (combustible applications) options are available.
  • Market-leading low-pressure drop
Falls City Laboratory Extraction Arms
Falls City, Oregon Fume Extraction Arm Optional Accessories

Falls City, Oregon Fume Extraction Arm Optional Accessories

Fume extraction arms have optional accessories that include:

Hood lights – Lights can be attached to the arm hood to provide better vision at the work point. Often used in welding applications.

Floor Stanchion - When the ceiling is too high, or there are no walls, a floor stanchion can be used to mount the arm.

Tube materials – For those arms using tubing, construction materials include painted steel, aluminum, stainless steel, P.P., or PVC. Extraction arms that use flex hoses can use clear, fire retardant, high temperature, or anti-static hoses.

Wall Mount - A wall bracket designed to mount the arm to any wall or beam within the facility.

Nozzles - To get even closer to source capture, suction nozzles and flexible suction nozzles are available.

Custom hoods – To maximize fume capture, standard circular or scoop-shaped hoods can be changed to a slotted design, rectangular, flat, or custom fabricated.

Ceiling Mount - For applications where arms are mounted/supported by the ceiling. The ceiling bracket varies in height depending on the height of the hard deck or Unistrut.

Falls

Falls City, Oregon Downdraft Tables, Benches, and Walk-In Enclosures

Dust and fume generating work areas within a facility can often be controlled with self-contained and moveable downdraft tables. Tables can be designed for tabletop downdraft only or combined with a backdraft airflow design for nuisance dust capture. Particulate micron size and the amount of collected particulate, smoke, or fume determines the air filtration systems selected, with typical options including throw-away filters, pulse-clean dust collectors, or wet collectors. For some applications, a downdraft bench that incorporates downdraft and backdraft exhaust can be designed for repetitive work processes.

Adding an enclosure around the dust source and containing the generated dust or fume in a walk-in booth minimizes the amount of air that needs to be cleaned. Dust control enclosures encapsulate processes where particulate, smoke, or fume are difficult to contain and are transported and dispersed within a room by cross drafts, mancoolers, compressed air clean-offs, or processing equipment like sanders and grinders.

Falls City, Oregon Stainless Steel Extraction Arms

Falls City, Oregon Stainless Steel Extraction Arms

Aggressive airstream chemistry may require the arms to be constructed of 304 stainless steel. The tubing and hood are stainless, with external adjustment joints at the hood and swivel joints. Arm assemblies have a wall mounting bracket and an internal damper for airflow adjustment and shutoff. The standard flex hose at the joints is an FDA Pur Antistatic hose. Stainless steel arm tube diameters vary from three to eight inches, and arm lengths from three feet up to fourteen feet, all suitable for washdown applications. 316 stainless steel construction is an available option.

  • Tubes, hood, internal shutoff damper, and duct connection collar are all constructed of 304SS
  • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
  • Clear anti-static FDA hose rated for 200 degrees Fahrenheit.
  • External joints are anodized aluminum.
  • 304 SS grab handle on the hood for easy mobility and positioning.
  • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', and 14'.
  • Available in hanging and benchtop models.

Falls City Telescopic Fume Extraction Arm

Telescopic extraction arms are designed to fit into confined spaces. They are used for those applications when the operator wants to "compress" the arm out of the way and pull it back to a working position. The unit will mount on the ceiling, wall, or floor stanchion. There are optional designs from which to choose. There is an arm with a ridged flex hose in six or eight-inch diameter having an operating range of seven feet to almost ten feet or a thin-walled tube design that is available in five-inch diameter and can telescope three feet out to seven feet. Both telescopic arm options would include a manual damper.

  • Swivel base
  • Arm diameters are 6" and 8", and the operating range (compression) is 4' to 7'.
  • Powder coated steel wall bracket is standard
  • Black hose rated up to 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
  • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
  • Internal is telescopic
  • The hood is powder-coated aluminum and includes a grab handle and shutoff damper built within
Falls City Telescopic Fume Extraction Arm
General Purpose Falls City, Oregon Industrial Extraction Arm

"General Purpose" Falls City, Oregon Industrial Extraction Arm

We label these arms a standard issue because they can be universally applied to most fume and dust extraction applications. The general-purpose arm is suitable for capturing smoke, dust, or any non-corrosive product. They are constructed of smooth powder-coated steel or aluminum tubing, a capture hood with adjustment grips, flex hose joint covers, and external adjustment brackets for the hood and swivel joints. The assemblies come standard with a wall mounting bracket but also have ceiling and floor support brackets available. An internal damper is included for airflow adjustment or shutoff. The arm mounting brackets allow for 180⁰ and 360⁰ rotation. Arm diameter options range from three to ten inches, and arm lengths vary from three to thirty-two feet. The maximum airstream temperature for these arms is about 180 degrees Fahrenheit.

Features and options:

  • A shutoff damper is built into the lower tube.
  • Grab handle around the hood that is aluminum powder-coated black.
  • Includes duct connection collar
  • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', and 14'.
  • Black hose rated for 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
  • An optional fume exhaust fan in aluminum, carbon steel, or PVC.
  • The wall bracket is powder-coated black.