Contact Us

    Belle Glade, Florida Stainless Steel Extraction Arms

    Belle Glade, Florida Stainless Steel Extraction Arms

    Aggressive airstream chemistry may require the arms to be constructed of 304 stainless steel. The tubing and hood are stainless, with external adjustment joints at the hood and swivel joints. Arm assemblies have a wall mounting bracket and an internal damper for airflow adjustment and shutoff. The standard flex hose at the joints is an FDA Pur Antistatic hose. Stainless steel arm tube diameters vary from three to eight inches, and arm lengths from three feet up to fourteen feet, all suitable for washdown applications. 316 stainless steel construction is an available option.

    • Tubes, hood, internal shutoff damper, and duct connection collar are all constructed of 304SS
    • External joints are anodized aluminum.
    • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', and 14'.
    • Available in hanging and benchtop models.
    • Clear anti-static FDA hose rated for 200 degrees Fahrenheit.
    • 304 SS grab handle on the hood for easy mobility and positioning.
    • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
    General Purpose Belle Glade, Florida Industrial Extraction Arm

    "General Purpose" Belle Glade, Florida Industrial Extraction Arm

    We label these arms a standard issue because they can be universally applied to most fume and dust extraction applications. The general-purpose arm is suitable for capturing smoke, dust, or any non-corrosive product. They are constructed of smooth powder-coated steel or aluminum tubing, a capture hood with adjustment grips, flex hose joint covers, and external adjustment brackets for the hood and swivel joints. The assemblies come standard with a wall mounting bracket but also have ceiling and floor support brackets available. An internal damper is included for airflow adjustment or shutoff. The arm mounting brackets allow for 180⁰ and 360⁰ rotation. Arm diameter options range from three to ten inches, and arm lengths vary from three to thirty-two feet. The maximum airstream temperature for these arms is about 180 degrees Fahrenheit.

    Features and options:

    • Grab handle around the hood that is aluminum powder-coated black.
    • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', and 14'.
    • A shutoff damper is built into the lower tube.
    • The wall bracket is powder-coated black.
    • Black hose rated for 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
    • An optional fume exhaust fan in aluminum, carbon steel, or PVC.
    • Includes duct connection collar

    Belle Glade ATEX Rated Fume Extraction Arms

    Explosion-rated extraction arms are available for the handling of explosive gases and dust. (The combustible materials need to be identified upfront to determine the arm selection and hose material, if there is particulate, is corrosive.) These extraction arms meet the requirements of the ATEX Directive 2014/34/E.U. Category 2 for gases and dust for Zones 1 and 21 (areas where an explosive atmosphere is likely to occur during regular operation). ATEX-rated fume arm tube diameters vary from four to eight inches, and arm lengths are optional from five feet up to twenty-three feet.

    • Model having a semi-transparent white P.U. hose for dust-related pollutants.
    • They are manufactured following ATEX directive 2014/34/E.U. Category 2 for gases and dust.
    • Arm diameters include 4", 5", 6", and 8", and arm lengths include 5', 7', 10', 13', 16', and 23'.
    • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
    • Flexible PE hose, fully grounded.
    • Models having black chemical resistance P.E. hose
    Belle Glade ATEX Rated Fume Extraction Arms
    Belle Glade, Florida Fume Extraction Arm Optional Accessories

    Belle Glade, Florida Fume Extraction Arm Optional Accessories

    Fume extraction arms have optional accessories that include:

    Custom hoods – To maximize fume capture, standard circular or scoop-shaped hoods can be changed to a slotted design, rectangular, flat, or custom fabricated.

    Floor Stanchion - When the ceiling is too high, or there are no walls, a floor stanchion can be used to mount the arm.

    Nozzles - To get even closer to source capture, suction nozzles and flexible suction nozzles are available.

    Tube materials – For those arms using tubing, construction materials include painted steel, aluminum, stainless steel, P.P., or PVC. Extraction arms that use flex hoses can use clear, fire retardant, high temperature, or anti-static hoses.

    Hood lights – Lights can be attached to the arm hood to provide better vision at the work point. Often used in welding applications.

    Ceiling Mount - For applications where arms are mounted/supported by the ceiling. The ceiling bracket varies in height depending on the height of the hard deck or Unistrut.

    Wall Mount - A wall bracket designed to mount the arm to any wall or beam within the facility.

    Belle Glade, Florida Fume Extraction Arm Mounting and Supports

    Belle Glade, Florida Fume Extraction Arm Mounting and Supports

    Fume extraction arms are continually moved, extended, and rotated, requiring them to be rigidly supported and mounted securely. A few factors affect mounting location: 1) the location of the fume source, 2) the coverage area for where the arm is used 3) the central system duct where the fume arm is connected.

    Mounting options include:

    Wall Mount - With duct systems running against a wall, mounting the arm (s) with brackets secured to a block wall or column is typical. If the central system duct is along the ceiling, on an outside wall, or mid-wall, there are designed brackets to fix the arm in place.

    Bench Mount - Exhaust duct running along the floor allows mounting to a bench or tabletop. This mount has a standard option bracket for attaching the arm. Another standard bench mount is on a portable air filter or dust collector.

    Ceiling Mount - Mounting the arms in the ceiling is an option if joists are present. A support weldment could be fabricated if a ceiling mount is a requirement. For low-weight short arms, the installation contractor can fabricate a wood fixture.

    Stanchion Mount - When arms are located in the center of a facility having high bay areas, a stanchion will allow the mounting of an arm and hold it rigidly in place.