Fume and Dust Extraction Arm Systems in Belgrade, Nebraska

Belgrade Fume industrial exhaust systems are designed to capture smoke, fume, dust, high-temperature air, and corrosive gases. These "pollutants" are ducted to an air cleaner (purification system) before discharge to the outside or returned to the workspace. Capturing air-entrained materials is best accomplished at the emission source, defined as source capture.

Belgrade, Nebraska Fume extraction arms with hoods or suction nozzles are the number one tool to maximize source capture efficiency. They capture the contaminated airstreams while getting close to the source without disrupting or slowing down the work process or collecting too much useable product. When the task or workpiece is difficult to access, in an isolated area, or along awkward points on an assembly line, extraction arms are a proven solution for maximum particulate, smoke, and fume collection.

Multiple arm designs are available depending on the airstream constituents. The parameters evaluated are temperature, explosivity, corrosiveness, and particulate, all factors determining the type of arm that should be selected for a process application. Matching your expected exhaust volume and arm useage with the required exhaust CFM, pressure loses, and airstream being captured is what we do. SysTech has successfully applied extraction arms for over thirty years and will assist with the correct selection for your process.

Fume and Dust Extraction Arm Systems in Belgrade, Nebraska
Belgrade, Nebraska Fume Extraction Arm Optional Accessories

Belgrade, Nebraska Fume Extraction Arm Optional Accessories

Fume extraction arms have optional accessories that include:

Nozzles - To get even closer to source capture, suction nozzles and flexible suction nozzles are available.

Hood lights – Lights can be attached to the arm hood to provide better vision at the work point. Often used in welding applications.

Wall Mount - A wall bracket designed to mount the arm to any wall or beam within the facility.

Floor Stanchion - When the ceiling is too high, or there are no walls, a floor stanchion can be used to mount the arm.

Ceiling Mount - For applications where arms are mounted/supported by the ceiling. The ceiling bracket varies in height depending on the height of the hard deck or Unistrut.

Tube materials – For those arms using tubing, construction materials include painted steel, aluminum, stainless steel, P.P., or PVC. Extraction arms that use flex hoses can use clear, fire retardant, high temperature, or anti-static hoses.

Custom hoods – To maximize fume capture, standard circular or scoop-shaped hoods can be changed to a slotted design, rectangular, flat, or custom fabricated.

Belgrade NE Fume Extraction Arms

Industrial exhaust systems for capturing smoke, fume, dust, high-temperature air, and corrosive gases.

General Purpose Belgrade, Nebraska Industrial Extraction Arm

"General Purpose" Belgrade, Nebraska Industrial Extraction Arm

We label these arms a standard issue because they can be universally applied to most fume and dust extraction applications. The general-purpose arm is suitable for capturing smoke, dust, or any non-corrosive product. They are constructed of smooth powder-coated steel or aluminum tubing, a capture hood with adjustment grips, flex hose joint covers, and external adjustment brackets for the hood and swivel joints. The assemblies come standard with a wall mounting bracket but also have ceiling and floor support brackets available. An internal damper is included for airflow adjustment or shutoff. The arm mounting brackets allow for 180⁰ and 360⁰ rotation. Arm diameter options range from three to ten inches, and arm lengths vary from three to thirty-two feet. The maximum airstream temperature for these arms is about 180 degrees Fahrenheit.

Features and options:

  • A shutoff damper is built into the lower tube.
  • Includes duct connection collar
  • The wall bracket is powder-coated black.
  • Grab handle around the hood that is aluminum powder-coated black.
  • An optional fume exhaust fan in aluminum, carbon steel, or PVC.
  • Black hose rated for 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
  • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', and 14'.

Contact Us

    Belgrade ATEX Rated Fume Extraction Arms

    Explosion-rated extraction arms are available for the handling of explosive gases and dust. (The combustible materials need to be identified upfront to determine the arm selection and hose material, if there is particulate, is corrosive.) These extraction arms meet the requirements of the ATEX Directive 2014/34/E.U. Category 2 for gases and dust for Zones 1 and 21 (areas where an explosive atmosphere is likely to occur during regular operation). ATEX-rated fume arm tube diameters vary from four to eight inches, and arm lengths are optional from five feet up to twenty-three feet.

    • Model having a semi-transparent white P.U. hose for dust-related pollutants.
    • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
    • Arm diameters include 4", 5", 6", and 8", and arm lengths include 5', 7', 10', 13', 16', and 23'.
    • Flexible PE hose, fully grounded.
    • They are manufactured following ATEX directive 2014/34/E.U. Category 2 for gases and dust.
    • Models having black chemical resistance P.E. hose
    Belgrade ATEX Rated Fume Extraction Arms
    Belgrade, Nebraska Fume Extraction Arm Mounting and Supports

    Belgrade, Nebraska Fume Extraction Arm Mounting and Supports

    Fume extraction arms are continually moved, extended, and rotated, requiring them to be rigidly supported and mounted securely. A few factors affect mounting location: 1) the location of the fume source, 2) the coverage area for where the arm is used 3) the central system duct where the fume arm is connected.

    Mounting options include:

    Wall Mount - With duct systems running against a wall, mounting the arm (s) with brackets secured to a block wall or column is typical. If the central system duct is along the ceiling, on an outside wall, or mid-wall, there are designed brackets to fix the arm in place.

    Bench Mount - Exhaust duct running along the floor allows mounting to a bench or tabletop. This mount has a standard option bracket for attaching the arm. Another standard bench mount is on a portable air filter or dust collector.

    Ceiling Mount - Mounting the arms in the ceiling is an option if joists are present. A support weldment could be fabricated if a ceiling mount is a requirement. For low-weight short arms, the installation contractor can fabricate a wood fixture.

    Stanchion Mount - When arms are located in the center of a facility having high bay areas, a stanchion will allow the mounting of an arm and hold it rigidly in place.