Exhaust Fans for Fume Extraction Arms in Azalea Park

Industrial exhaust system arms often need a connection to an exhaust fan for isolated applications or when needed for additional static resistance when connecting to an existing duct system. Fan CFM and static pressure must be examined in both cases to maintain system performance. When coupling with an exhaust fan, it should be constructed of similar or compatible materials to the extraction arm.

Cast Aluminum Pressure Blowers

Cast aluminum pressure blowers are typically supplied by manufacturers where there is a non-corrosive airstream. They are light, come in a wide range of designs, are compact, and are AMCA B spark-resistant as standard. Motors are available in single and three-phase TEFC and EXP frames.

Carbon Steel Fume Exhauster

If conditions of the airstream are suitable, a carbon steel painted fan is selected in a direct drive arrangement with a horizontal mount configuration that requires minimal space. Steel blowers have the option for AMCA construction up to AMCA A and 304 and 316 SS construction. Motors are available in single and three-phase TEFC and EXP frames.

Industrial Plastic Fume Exhaust Fans

Corrosive environments require materials of construction that will not degrade over time. Plastic construction is misunderstood as fragile, but industrial-grade designs are compatible with the harshest environment. The plastics typically used for construction are PVC or polypropylene (P.P.) and are an excellent choice for the efficient conveyance of corrosive, chemically laden, humid, or polluted gases, fumes, and air. Motors are available in single and three-phase TEFC and EXP frames.

Fume Extraction Arm Exhaust Fans in Azalea Park

Contact Us

    Azalea Park Telescopic Fume Extraction Arm

    Telescopic extraction arms are designed to fit into confined spaces. They are used for those applications when the operator wants to "compress" the arm out of the way and pull it back to a working position. The unit will mount on the ceiling, wall, or floor stanchion. There are optional designs from which to choose. There is an arm with a ridged flex hose in six or eight-inch diameter having an operating range of seven feet to almost ten feet or a thin-walled tube design that is available in five-inch diameter and can telescope three feet out to seven feet. Both telescopic arm options would include a manual damper.

    • Black hose rated up to 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
    • The hood is powder-coated aluminum and includes a grab handle and shutoff damper built within
    • Swivel base
    • Internal is telescopic
    • Powder coated steel wall bracket is standard
    • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
    • Arm diameters are 6" and 8", and the operating range (compression) is 4' to 7'.
    Azalea Park Telescopic Fume Extraction Arm

    Azalea Park Laboratory Extraction Arms

    The laboratory extraction arm is comprised of thin-wall anodized aluminum tubes with polypropylene swivel joints. A frequent option selection is all polypropylene construction with stainless steel airstream components for highly corrosive airstreams. Additionally, these arms may be constructed of conductive polypropylene material for spark resistance and ATEX-rated explosive applications. Arm tube diameters range from two to four inches, and arm lengths range from two feet up to eight and a half feet. Arms can be paired with a wall or ceiling bracket, several optional hoods, or a suction nozzle. Azalea Park, Florida Laboratory bench mount arms are an option and are available in three and four-inch diameter tubes up to six feet in length.

    • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
    • Various hood options for more efficient source capture include dome hoods, square hoods, flat screen hoods, metal hoods, and suction nozzles.
    • Market-leading low-pressure drop
    • Arm diameters include 2", 3", and 4", and arm lengths include 25", 30", 39", 45",51", 53", 59", 65", 75", 79", 83", and 104".
    • Wall brackets, ceiling brackets, and table mount brackets are available.
    • Polypropylene (P.P.), ESD (spark forming applications), and ATEX (combustible applications) options are available.
    Azalea Park Laboratory Extraction Arms

    New and Retrofitted Extraction Arm Systems in Azalea Park

    When you install a new fume extraction arm or arms, it improves air cleaning system performance, resulting in a cleaner work environment. Expectations can be met if all-important selection factors are considered and limitations for capture are pointed out.

    If you are repairing, replacing, or adding a new arm or arms, to an existing system, the critical components of the fume exhaust system should be reviewed, including the duct system, the exhaust fan (s), and the air cleaning device. Systems are only as efficient as their individual parts, and SysTech will review your components with you to evaluate if your system is operating at peak performance.

    New and Retrofitted Extraction Arm Systems in Azalea Park
    General Purpose Azalea Park, Florida Industrial Extraction Arm

    "General Purpose" Azalea Park, Florida Industrial Extraction Arm

    We label these arms a standard issue because they can be universally applied to most fume and dust extraction applications. The general-purpose arm is suitable for capturing smoke, dust, or any non-corrosive product. They are constructed of smooth powder-coated steel or aluminum tubing, a capture hood with adjustment grips, flex hose joint covers, and external adjustment brackets for the hood and swivel joints. The assemblies come standard with a wall mounting bracket but also have ceiling and floor support brackets available. An internal damper is included for airflow adjustment or shutoff. The arm mounting brackets allow for 180⁰ and 360⁰ rotation. Arm diameter options range from three to ten inches, and arm lengths vary from three to thirty-two feet. The maximum airstream temperature for these arms is about 180 degrees Fahrenheit.

    Features and options:

    • A shutoff damper is built into the lower tube.
    • Grab handle around the hood that is aluminum powder-coated black.
    • Black hose rated for 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
    • The wall bracket is powder-coated black.
    • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', and 14'.
    • Includes duct connection collar
    • An optional fume exhaust fan in aluminum, carbon steel, or PVC.