Aleknagik ATEX Rated Fume Extraction Arms

Explosion-rated extraction arms are available for the handling of explosive gases and dust. (The combustible materials need to be identified upfront to determine the arm selection and hose material, if there is particulate, is corrosive.) These extraction arms meet the requirements of the ATEX Directive 2014/34/E.U. Category 2 for gases and dust for Zones 1 and 21 (areas where an explosive atmosphere is likely to occur during regular operation). ATEX-rated fume arm tube diameters vary from four to eight inches, and arm lengths are optional from five feet up to twenty-three feet.

  • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
  • They are manufactured following ATEX directive 2014/34/E.U. Category 2 for gases and dust.
  • Arm diameters include 4", 5", 6", and 8", and arm lengths include 5', 7', 10', 13', 16', and 23'.
  • Flexible PE hose, fully grounded.
  • Models having black chemical resistance P.E. hose
  • Model having a semi-transparent white P.U. hose for dust-related pollutants.
Aleknagik ATEX Rated Fume Extraction Arms

Contact Us

    Aleknagik AK Fume Extraction Arms

    Industrial exhaust systems for capturing smoke, fume, dust, high-temperature air, and corrosive gases.

    New and Retrofitted Extraction Arm Systems in Aleknagik

    When you install a new fume extraction arm or arms, it improves air cleaning system performance, resulting in a cleaner work environment. Expectations can be met if all-important selection factors are considered and limitations for capture are pointed out.

    If you are repairing, replacing, or adding a new arm or arms, to an existing system, the critical components of the fume exhaust system should be reviewed, including the duct system, the exhaust fan (s), and the air cleaning device. Systems are only as efficient as their individual parts, and SysTech will review your components with you to evaluate if your system is operating at peak performance.

    New and Retrofitted Extraction Arm Systems in Aleknagik
    Aleknagik,

    Aleknagik, Alaska Downdraft Tables, Benches, and Walk-In Enclosures

    Dust and fume generating work areas within a facility can often be controlled with self-contained and moveable downdraft tables. Tables can be designed for tabletop downdraft only or combined with a backdraft airflow design for nuisance dust capture. Particulate micron size and the amount of collected particulate, smoke, or fume determines the air filtration systems selected, with typical options including throw-away filters, pulse-clean dust collectors, or wet collectors. For some applications, a downdraft bench that incorporates downdraft and backdraft exhaust can be designed for repetitive work processes.

    Adding an enclosure around the dust source and containing the generated dust or fume in a walk-in booth minimizes the amount of air that needs to be cleaned. Dust control enclosures encapsulate processes where particulate, smoke, or fume are difficult to contain and are transported and dispersed within a room by cross drafts, mancoolers, compressed air clean-offs, or processing equipment like sanders and grinders.

    General Purpose Aleknagik, Alaska Industrial Extraction Arm

    "General Purpose" Aleknagik, Alaska Industrial Extraction Arm

    We label these arms a standard issue because they can be universally applied to most fume and dust extraction applications. The general-purpose arm is suitable for capturing smoke, dust, or any non-corrosive product. They are constructed of smooth powder-coated steel or aluminum tubing, a capture hood with adjustment grips, flex hose joint covers, and external adjustment brackets for the hood and swivel joints. The assemblies come standard with a wall mounting bracket but also have ceiling and floor support brackets available. An internal damper is included for airflow adjustment or shutoff. The arm mounting brackets allow for 180⁰ and 360⁰ rotation. Arm diameter options range from three to ten inches, and arm lengths vary from three to thirty-two feet. The maximum airstream temperature for these arms is about 180 degrees Fahrenheit.

    Features and options:

    • A shutoff damper is built into the lower tube.
    • Grab handle around the hood that is aluminum powder-coated black.
    • Includes duct connection collar
    • Black hose rated for 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
    • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', and 14'.
    • The wall bracket is powder-coated black.
    • An optional fume exhaust fan in aluminum, carbon steel, or PVC.