Exhaust Fans for Fume Extraction Arms in Admire

Industrial exhaust system arms often need a connection to an exhaust fan for isolated applications or when needed for additional static resistance when connecting to an existing duct system. Fan CFM and static pressure must be examined in both cases to maintain system performance. When coupling with an exhaust fan, it should be constructed of similar or compatible materials to the extraction arm.

Cast Aluminum Pressure Blowers

Cast aluminum pressure blowers are typically supplied by manufacturers where there is a non-corrosive airstream. They are light, come in a wide range of designs, are compact, and are AMCA B spark-resistant as standard. Motors are available in single and three-phase TEFC and EXP frames.

Carbon Steel Fume Exhauster

If conditions of the airstream are suitable, a carbon steel painted fan is selected in a direct drive arrangement with a horizontal mount configuration that requires minimal space. Steel blowers have the option for AMCA construction up to AMCA A and 304 and 316 SS construction. Motors are available in single and three-phase TEFC and EXP frames.

Industrial Plastic Fume Exhaust Fans

Corrosive environments require materials of construction that will not degrade over time. Plastic construction is misunderstood as fragile, but industrial-grade designs are compatible with the harshest environment. The plastics typically used for construction are PVC or polypropylene (P.P.) and are an excellent choice for the efficient conveyance of corrosive, chemically laden, humid, or polluted gases, fumes, and air. Motors are available in single and three-phase TEFC and EXP frames.

Fume Extraction Arm Exhaust Fans in Admire

Admire Telescopic Fume Extraction Arm

Telescopic extraction arms are designed to fit into confined spaces. They are used for those applications when the operator wants to "compress" the arm out of the way and pull it back to a working position. The unit will mount on the ceiling, wall, or floor stanchion. There are optional designs from which to choose. There is an arm with a ridged flex hose in six or eight-inch diameter having an operating range of seven feet to almost ten feet or a thin-walled tube design that is available in five-inch diameter and can telescope three feet out to seven feet. Both telescopic arm options would include a manual damper.

  • Arm diameters are 6" and 8", and the operating range (compression) is 4' to 7'.
  • The hood is powder-coated aluminum and includes a grab handle and shutoff damper built within
  • Internal is telescopic
  • Black hose rated up to 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
  • Swivel base
  • Powder coated steel wall bracket is standard
  • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
Admire Telescopic Fume Extraction Arm

Admire Laboratory Extraction Arms

The laboratory extraction arm is comprised of thin-wall anodized aluminum tubes with polypropylene swivel joints. A frequent option selection is all polypropylene construction with stainless steel airstream components for highly corrosive airstreams. Additionally, these arms may be constructed of conductive polypropylene material for spark resistance and ATEX-rated explosive applications. Arm tube diameters range from two to four inches, and arm lengths range from two feet up to eight and a half feet. Arms can be paired with a wall or ceiling bracket, several optional hoods, or a suction nozzle. Admire, Kansas Laboratory bench mount arms are an option and are available in three and four-inch diameter tubes up to six feet in length.

  • Arm diameters include 2", 3", and 4", and arm lengths include 25", 30", 39", 45",51", 53", 59", 65", 75", 79", 83", and 104".
  • Wall brackets, ceiling brackets, and table mount brackets are available.
  • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
  • Polypropylene (P.P.), ESD (spark forming applications), and ATEX (combustible applications) options are available.
  • Market-leading low-pressure drop
  • Various hood options for more efficient source capture include dome hoods, square hoods, flat screen hoods, metal hoods, and suction nozzles.
Admire Laboratory Extraction Arms

Economical Industrial Extraction Arms in Admire KS


These extraction arms serve a similar function as the general-purpose extraction arm but are constructed with a flexible hose instead of metal tubing. This arm has cost savings, but some optional features are unavailable. These arms were designed for light-duty, intermittent applications and have limitations on some airstream constituents. Importantly, each application is reviewed upfront by SysTech will guide you through the selection process safely. Hose diameter alternatives range from four to eight inches, and arm lengths range from five to thirty-six feet. The standard hose material is blue PVC or white PVC with an option for PE-coated polyamide fabric for mild corrosive applications. Custom sizes can be designed using various parts for different arm models combined to make a new arm design.

Features and options:

  • Hood designed for maximum capture efficiency and extraction
  • Arm diameters include 4", 5", 6", and 8", and arm lengths include 5', 7', 10', 13', 16', 23', 30', and 36'.
  • External arm support
  • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
  • High positional stability
  • Lowest possible pressure drop, which helps save energy and lowers sound levels
  • Lightweight construction balanced by two gas springs.
  • Unique ease of maneuverability

New and Retrofitted Extraction Arm Systems in Admire

When you install a new fume extraction arm or arms, it improves air cleaning system performance, resulting in a cleaner work environment. Expectations can be met if all-important selection factors are considered and limitations for capture are pointed out.

If you are repairing, replacing, or adding a new arm or arms, to an existing system, the critical components of the fume exhaust system should be reviewed, including the duct system, the exhaust fan (s), and the air cleaning device. Systems are only as efficient as their individual parts, and SysTech will review your components with you to evaluate if your system is operating at peak performance.

New and Retrofitted Extraction Arm Systems in Admire
Admire,

Admire, Kansas Downdraft Tables, Benches, and Walk-In Enclosures

Dust and fume generating work areas within a facility can often be controlled with self-contained and moveable downdraft tables. Tables can be designed for tabletop downdraft only or combined with a backdraft airflow design for nuisance dust capture. Particulate micron size and the amount of collected particulate, smoke, or fume determines the air filtration systems selected, with typical options including throw-away filters, pulse-clean dust collectors, or wet collectors. For some applications, a downdraft bench that incorporates downdraft and backdraft exhaust can be designed for repetitive work processes.

Adding an enclosure around the dust source and containing the generated dust or fume in a walk-in booth minimizes the amount of air that needs to be cleaned. Dust control enclosures encapsulate processes where particulate, smoke, or fume are difficult to contain and are transported and dispersed within a room by cross drafts, mancoolers, compressed air clean-offs, or processing equipment like sanders and grinders.