Ada Laboratory Extraction Arms

The laboratory extraction arm is comprised of thin-wall anodized aluminum tubes with polypropylene swivel joints. A frequent option selection is all polypropylene construction with stainless steel airstream components for highly corrosive airstreams. Additionally, these arms may be constructed of conductive polypropylene material for spark resistance and ATEX-rated explosive applications. Arm tube diameters range from two to four inches, and arm lengths range from two feet up to eight and a half feet. Arms can be paired with a wall or ceiling bracket, several optional hoods, or a suction nozzle. Ada, Ohio Laboratory bench mount arms are an option and are available in three and four-inch diameter tubes up to six feet in length.

  • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
  • Wall brackets, ceiling brackets, and table mount brackets are available.
  • Various hood options for more efficient source capture include dome hoods, square hoods, flat screen hoods, metal hoods, and suction nozzles.
  • Polypropylene (P.P.), ESD (spark forming applications), and ATEX (combustible applications) options are available.
  • Market-leading low-pressure drop
  • Arm diameters include 2", 3", and 4", and arm lengths include 25", 30", 39", 45",51", 53", 59", 65", 75", 79", 83", and 104".
Ada Laboratory Extraction Arms

Contact Us

    Ada, Ohio Weld Fume Extraction Arm

    Ada, Ohio Weld Fume Extraction Arm

    The demand for weld smoke extraction arms is always high and mandates an arm category. Depending on the application, different designs use either smooth wall or flex hose tubing. Both designs use external positioning joints and a hood with an internal adjustable damper. The units are typically wall-mounted but have ceiling and floor support bracket options. Arm diameter options range from six to eight inches, and arm lengths vary from three feet up to thirty-six feet. Personal weld fume packages include a single extraction arm, exhaust fan, and air filter.

    • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
    • Standard units include a wall bracket. Ceiling mount options are available.
    • Low-pressure drop
    • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', 14', 16', 23', 30', and 36'.
    • Shut off dampers built internally.

    Ada Telescopic Fume Extraction Arm

    Telescopic extraction arms are designed to fit into confined spaces. They are used for those applications when the operator wants to "compress" the arm out of the way and pull it back to a working position. The unit will mount on the ceiling, wall, or floor stanchion. There are optional designs from which to choose. There is an arm with a ridged flex hose in six or eight-inch diameter having an operating range of seven feet to almost ten feet or a thin-walled tube design that is available in five-inch diameter and can telescope three feet out to seven feet. Both telescopic arm options would include a manual damper.

    • The hood is powder-coated aluminum and includes a grab handle and shutoff damper built within
    • Powder coated steel wall bracket is standard
    • Internal is telescopic
    • Swivel base
    • Optional fume exhaust fans in aluminum, carbon steel, or PVC.
    • Arm diameters are 6" and 8", and the operating range (compression) is 4' to 7'.
    • Black hose rated up to 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
    Ada Telescopic Fume Extraction Arm
    Ada, Ohio Fume Extraction Arm Mounting and Supports

    Ada, Ohio Fume Extraction Arm Mounting and Supports

    Fume extraction arms are continually moved, extended, and rotated, requiring them to be rigidly supported and mounted securely. A few factors affect mounting location: 1) the location of the fume source, 2) the coverage area for where the arm is used 3) the central system duct where the fume arm is connected.

    Mounting options include:

    Wall Mount - With duct systems running against a wall, mounting the arm (s) with brackets secured to a block wall or column is typical. If the central system duct is along the ceiling, on an outside wall, or mid-wall, there are designed brackets to fix the arm in place.

    Bench Mount - Exhaust duct running along the floor allows mounting to a bench or tabletop. This mount has a standard option bracket for attaching the arm. Another standard bench mount is on a portable air filter or dust collector.

    Ceiling Mount - Mounting the arms in the ceiling is an option if joists are present. A support weldment could be fabricated if a ceiling mount is a requirement. For low-weight short arms, the installation contractor can fabricate a wood fixture.

    Stanchion Mount - When arms are located in the center of a facility having high bay areas, a stanchion will allow the mounting of an arm and hold it rigidly in place.

    General Purpose Ada, Ohio Industrial Extraction Arm

    "General Purpose" Ada, Ohio Industrial Extraction Arm

    We label these arms a standard issue because they can be universally applied to most fume and dust extraction applications. The general-purpose arm is suitable for capturing smoke, dust, or any non-corrosive product. They are constructed of smooth powder-coated steel or aluminum tubing, a capture hood with adjustment grips, flex hose joint covers, and external adjustment brackets for the hood and swivel joints. The assemblies come standard with a wall mounting bracket but also have ceiling and floor support brackets available. An internal damper is included for airflow adjustment or shutoff. The arm mounting brackets allow for 180⁰ and 360⁰ rotation. Arm diameter options range from three to ten inches, and arm lengths vary from three to thirty-two feet. The maximum airstream temperature for these arms is about 180 degrees Fahrenheit.

    Features and options:

    • Black hose rated for 195 degrees Fahrenheit (intermittent 260 degrees Fahrenheit)
    • A shutoff damper is built into the lower tube.
    • Includes duct connection collar
    • The wall bracket is powder-coated black.
    • An optional fume exhaust fan in aluminum, carbon steel, or PVC.
    • Grab handle around the hood that is aluminum powder-coated black.
    • Arm diameters include 3", 4", 5", 6", and 8", and arm lengths include 3', 5', 7', 8', 10', and 14'.